SPL / Leq Meter Component (BETA)

The SPL / Leq meter provides the ability to measure sound loudness using two different methods. The SPL meter is an exponentially averaging sound level meter with an integration time-constant, referred to as the time-weighting. The Leq meter is a continuous equivalent sound level meter of the integrating-averaging type with an integration time.

Calibration Procedure

The meter is calibrated using pink noise. This source can be external to Q-SYS, or can be generated by Q-SYS using the Pink Noise generator component and played out through the system.

  1. Set the pink noise at a nominal level and wait at least twice the Time Weighting (for the SPL meter) or the Leq Time (for the Leq meter) for the meter value to settle.
  2. Use an external, calibrated, SPL meter to measure the level of the pink noise.
  3. Ensure that both external and Q-SYS meters use the same Time and Frequency Weighting!
  4. Enter the SPL level using the Reference Level control.
  5. Click the Calibrate button and verify that both external and Q-SYS meters show the same level. The Q-SYS meter is calibrated.

Controls

NOTE:  Depending on the Frequency Weighting setting, the Level units of measure will change. Linear = dB, ANSI S1.42 A = dBA, ANSI S1.42 C = dBC. In this topic, all units are listed as dB regardless of the Frequency Weighting setting.

The following controls are common to both SPL and Leq meter types.

Control

Function

Default/Range

Reference Level

dB

The Reference Level is used to calibrate the meter. Set this level to the level measured by an external, calibrated, SPL meter. Refer to the Calibration Procedure for details.

Default = 85

Range = 0 to 140

Calibrate

After setting the Reference Level, click this button to calibrate the meter.

Refer to the Calibration Procedure for details.

N/A

Reset Max

Click this button to reset the maximum level.

N/A

Capture Click this button to capture the current level reading. N/A

SPL Meter Controls

The Meter Type in the Properties must be set to SPL to see the following controls.

Control

Function

Default/Range

Time Weighting

(seconds)

This control determines the meter’s response time to changing levels. There are two standard weightings, Slow (1s) and Fast (125ms).

Default = 1.00

Range =

100ms to 10.0s

Sound Pressure Level

dB

Displays the current level.

Default = N/A

Range =

0 to 100

up to

40 to 140

Max Hold Time

(seconds)

Sets the time interval to reset the maximum level.

Default = 10

Range = 1 to 100

Infinite Max Hold

When on, this button causes the Max Hold Time to be ignored. The maximum level is held until manually reset.

Default = Off

Range = Off/On

Max SPL

dB

Keeps track of the maximum SPL level over time.

Default = N/A

Range = 0 to 120

 

Leq Meter Controls

The Meter Type in the Properties must be set to Leq to see the following controls.

Control

Function

Default/Range

Equivalent Continuous Sound Level

This graph shows a time chart of the most recent levels.

Default = N/A

Range =

0 to 100

up to

40 to 140

Leq Time

(Seconds)

Determines the meter’s time interval over which the level is integrated and averaged.

Default = 1.00

Range =

100ms to 3600s

Max Leq

dB

Tracks the maximum Leq level over time.

Max Leq is on infinite hold, and can only be reset manually with the Reset Max button.

Default = N/A

Range =

0 to 100

up to

40 to 140

Leq

dB

Displays the current level.

Default = N/A

Range = 0 to 140

Properties

Property

Function

Choices

Meter Type

Exponentially averaging SPL meter

or

Integrating-averaging Leq meter

SPL / Leq

 

Frequency Weighting

  • Linear or flat frequency weighting means that the input signal is not filtered before the level is calculated.
  • An A-weighting filter typically emphasizes frequencies where the human ear is most sensitive, around 3–6 kHz. In addition, the filter attenuates frequencies where the ear is less sensitive, that is, very high and very low frequencies.
  • A C-weighting filter includes more of the low frequencies, and is used at higher sound levels where the lower frequencies can be heard better by the human ear.

Linear (flat)

ANSI S1.42 A

ANSI S1.42 C

Level Range

The meter’s useful range is 100dB. Depending on the nominal expected sound pressure level, this range can be adjusted from 0 - 100 dB to 40 - 140 dB.

0 - 100

10 - 110

20 - 120

30 - 130

40 - 140

Control Pins

The following Control Pins are common to both SPL and Leq meter types.

Pin Name

Value

String

Position

Pins Available

Calibrate Level

(Momentary)

0

1

false

true

0

1

Input / Output

Capture Level

(Momentary)

0

1

false

true

0

1

Input / Output

Captured Level

dB

0 to 140

0 dB to 120 dB

0.00 to 1.00

Output

External Reference Level

dB

0 to 140

0 dB to 140 dB

0.00 to 1.00

Input / Output

Maximum Level

dB

0 to 140

0 dB to 120 dB

0.00 to 1.00

Output

Reset Maximum Level

0

1

false

true

0

1

Input / Output

SPL Meter

The Meter Type in the Properties must be set to SPL to see the following control pins.

Pin Name

Value

String

Position

Pins Available

Infinite Maximum Hold

0

1

false

true

0

1

Input / Output
Maximum Hold Time

1 to 100

1.00s to 100s

0.00 to 1.00

Input / Output

Sound Pressure Level

dB

0 to 100

up to

40 to 140

0 dB to 100 dB

up to

40 dB to 140 dB

0.00 to 1.00

Output
Time Weighting

0.100 to 10.0

100ms to 10.0s

0.00 to 1.00

Input / Output

Leq Meter

The Meter Type in the Properties must be set to Leq to see the following control pins.

Pin Name

Value

String

Position

Pins Available

Leq (dBA)

0 to 100

up to

40 to 140

0 dBA to 100 dBA

up to

40 dBA to 140 dBA

0.00 to 1.00

Output
Leq Time

0.100 to 3600

100ms to 3600s

0.00 to 1.00

Input / Output
Level Updated 1

0

1

false

true

0

1

Output
1. The Level is updated at the interval set by the Leq Time control. This output is available only on this Control Pin, to be used in scripts that post-process and/or log the measured level.

Logging Leq Measurements

The measured Leq can be exposed via the Leq, Leq Time, and Level Updated control pins wired to a custom script that logs the values to one or more files.

Script Example

(input 1 = Leq, input 2 = Leq Time, input 3 = Level Updated)
(The hidden Level Updated control toggles between 0 and 1 when a new Leq value is available which is every Leq Time period.)
os = require "os"
io = require "io"
Controls.Inputs[3].EventHandler = function()
     time = string.format( "%.1f", Controls.Inputs[2].Value )
     level = string.format( "%.1f", Controls.Inputs[1].Value )
     filename = "/media/media/Audio/" .. "A_weighted_Leq_" .. os.date( "%Y_%m_%d" ) .. ".csv"
     data = os.date( "%H:%M:%S" ) .. "," .. time .. "," .. level .. "\r\n"
     file = io.open( filename, "a+" )
     file:write( data )
     file:close()
end

 


 